NetApp V3100 Series Specification

Technical Highlights
Maximum RAID Group Sizes1 RAID-DP ® (high performance RAID 6)
FC: 28 (26 data disks plus 2 parity disks)
SATA: 16 (14 data disks plus 2 parity disks)

RAID 42
FC: 14 (13 data disks plus 1 parity disk)
SATA: 7 (6 data disks plus 1 parity disk)

SyncMirror ® (high resiliency RAID 1)
Options: *
  1. RAID-DP + RAID 1
  2. RAID 4 + RAID 1
  3. RAID 0 + RAID 1
SAN Protocol Support Fibre Channel Protocol (FCP) for SCSI (4/2/1Gb); fabric-attached and direct-attached; IP SAN (iSCSI)
File Service Protocol Support NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft® CIFS
Other Protocol Support HTTP 1.0, HTTP 1.1 virtual hosts
LUNs Up to 2,048 server host LUNs
FlexVol® Volumes Up to 500 per controller
Volume/Aggregate Size3 16TB
Snapshot™ Copies Up to 127,000
Number of Supported SAN Hosts Up to 12 ports4 per controller configured as front-end (host) connectivity ports
Up to 12 directly connected servers5 (per controller and per active-active configuration)
Up to 256 SAN connected servers (per controller and per active-active configuration)
Supported Configurations Highly Available Controller Configurations
Active-active controller with controller failover6, active-active controller with stretch (non switch) MetroCluster, active-active controller with fabric-attached MetroCluster
Highly Available Back-End (Disk) Configurations
Dual-path, multipath HA storage
Reliability Redundant hot-swappable controllers, cooling fans, power supplies, optics, and RJ-45 ports
Management Onboard serial console, diagnostic LED, full-duplex 10/100Base-T Ethernet remote LAN management port with RLM and onboard management interfaces, SNMP, telnet, SSH, HTTP, Web (SSL), host scripting, e-mail alerts
Security Virus Protection
Authentication: Kerberos (MIT/Active Directory)
Authorization: LDAP, NIS
Auditing: File access logging
Encryption: IPSec, SSL, SSH, SMB signing
Role-Based Access Control (RBAC)

1RAID-DP: RAID 4 is not supported with third-party storage arrays for V-Series
2RAID-DP is the recommended configuration for drives greater than 144GB.
3Maximum volume/aggregate size is calculated using base 2 arithmetic (1TB = 240 bytes).
4Requires Data ONTAP® 7.3
5Requires Data ONTAP 7.3
6For more information about cluster configurations, refer to http://now.netapp.com/NOW/knowledge/docs/ontap/rel704/html/filer/cluster/index.htm.
7NetApp® disks will be supported in V-Series and requires Data ONTAP 7.3.

 

Onboard I/O Ports/Slots
V3170
V3140
 
Active-Active
Configuration
Single Controller
Active-Active
Configuration
Single Controller
Fibre Channel Ports
(target or initiator)
8 ports
1, 2, or 4Gb
(auto-sensing)
4 ports
1, 2, or 4Gb
(auto-sensing)
8 ports
1, 2, or 4Gb
(auto-sensing)
4 ports
1, 2, or 4Gb
(auto-sensing)
GbE Ports
4
2
4
2
I/O Expansion Slots
8
4
8
4

 

I/O Card Support
V3170
V3140
 
Active-Active
Configuration
Single Controller
Active-Active
Configuration
Single Controller
2-Port FC Disk Adapters (max.)
8
4
8
4
2-Port 4Gb FC Target Adapters (max.)
4
2
4
2
4-Port 4Gb FC Disk/Tape HBAs (max.)
8
4
8
4
4-Port 4Gb FC Target Adapter (max.)8
6
3
6
3
2-Port Ultra320 SCSI Tape HBA
8
4
8
4
Optional Network/SAN Cards (max.)
2-Port FC Tape Adapters
4-Port 1GbE (copper) Cards
4-Port 1GbE TOE (copper) Cards
2-Port 10GbE TOE (fiber) Cards
2-Port 1GbE (copper or fiber) Cards
2-Port 1Gb iSCSI (copper or fiber) HBA

8
8
8
8
8
8

4
4
4
4
4
4

8
8
8
8
8
8

4
4
4
4
4
4
Performance Acceleration Module
8
4
4
2

 

V3100 Storage Array Subsystem Specifications9
Storage Interface/Data Rate PCI-Based Fibre Channel Fabric and Fibre Channel-Arbitrated Loop (FC-AL)/1 to 4Gb/sec
Storage Arrays

IBM
SAN Volume controller, Enterprise Storage Server (ESS), DS 4000 storage
HDS
USP Platform, AMS, Lightning Series, Thunder Series, SANRISE Series (Japan Only)
HP
StorageWorks XP Arrays, StorageWorks Enterprise Virtual Arrays
EMC
Symmetrix, Clariion
Fujitsu
ETERNUS Platform
3PAR
InServ Family
SUN
StorageTek

 

V3100 Back-End Array SAN Switch Connectivity9
Vendor Model
Brocade Silkworm 48000, 24000, 12000, 7500, 5000, 4900 4100, 4020, 4012, 3900,3850, 3800, 3250, 3200, 3016, 3014, 2800, 200E
Cisco MDS 9513, 9509, 9506, 9216, 9216A, 9216i, 9140, 9124, 9120, 9020
McDATA Sphereon 4700, 4500, 4400, 4300
Intrepid 6140, 6064

8 Requires Data ONTAP 7.3.
9 See V-Series hardware compatibility matrix for latest hardware and SAN switch connectivity support: http://now.netapp.com/NOW/knowledge/docs/V-Series/supportmatrix/V-Series_SupportMatrix.pdf.

 

Software
Operating System NetApp Data ONTAP®
Operating Systems Supported Windows® 2000, Windows Server 2003, Windows XP, Linux®, Sun™ Solaris™, AIX, HP-UX, Mac® OS, VMware ESX
Software Features Standard
RAID manager, including RAID-DP
Snapshot
Fast Boot
NIS
DNS
FilerView®
FlexVol
FlexShare
Deduplication
Network Data Management Protocol (NDMP)
Maintenance Center

Licensed10
FlexClone®
FlexCache
MultiStore®
SyncMirror
NearStore® on FAS

Protection Software
SnapMirror®
SnapRestore®
SnapVault®
Open Systems SnapVault
LockVault
SnapLock® Compliance11
SnapLock Enterprise
MetroCluster

Management Software
SnapManager® for Microsoft Exchange
SnapManager for Microsoft SQL Server™
SnapManager for Oracle
SnapManager for Microsoft SharePoint® Server
SnapManager for SAP®
SnapManager for Virtual Infrastructure
SnapValidator for Oracle
ApplianceWatch
SnapDrive® for UNIX®
SnapDrive for Windows

Protection Manager
VFM® (Virtual File Manager™) EE
VFM ME
CommandCentral™ Storage
File Storage Resource Manager
Operations Manager
Provisioning Manager
Single Mailbox Recovery  

 

Disk Drive Storage Expansion Shelf Specifications12
Storage Expansion Shelves Supported
(Fibre Channel, SATA)
FC:          DS14mk4 FC
DS14mk2 FC
SATA:    DS14mk2 AT
All shelves have 14 bays for 3.5” low-profile FC or SATA disk drives
Storage Expansion Shelf to Controller Interface Fibre Channel-Arbitrated Loop (FC-AL)
Storage Expansion Shelf Configurations New System Configurations
FC:          DS14mk4 FC with ESH4 (Embedded Switched Hub 4) Electronics
SATA:     DS14mk2 AT with AT-FCX Electronics
Supported via Upgrade Migrations from Installed Systems
FC:          DS14mk4 FC with ESH4 Electronics
DS14mk2 FC with ESH4 or ESH2 Electronics
SATA:     DS14mk2 AT with AT-FCX Electronics
Power Supply/Cooling Fans Dual, redundant, hot-pluggable, integrated power supply/fan assemblies13
AC Power/Maximum Current14 SATA:     7200 RPM drives: 3.01/1.51/7.4A @ 100VAC/200VAC/-40VDC
FC:         10,000 RPM drives: 3.09/1.56/7.61A @ 100VAC/200VAC/-40VDC
FC:         15,000 RPM drives: 3.96/1.94/10.22ª @ 100VAC/200VAC/-40VDC
Thermal Rating15 SATA:     7200 RPM drives: 1017 BTU/hr
FC:        10,000 RPM drives: 1043 BTU//hr
FC:        15,000 RPM drives: 1394 BTU/hr
Operating Acoustic Noise 49 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
Dimensions (height/width/depth) 3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm)
Weight 77 lb (35 kg) fully loaded

10 For more information about available software, refer to www.netapp.com/products/software.html.
11 V-Series does not support SnapLock Compliance with third-party storage arrays, only with NetApp disks.
12 NetApp disks will be supported in V-Series and requires Data ONTAP 7.3
13 For detailed disk shelf specifications, refer to http://now.netapp.com/NOW/knowledge/docs/hardware/NetApp/site/guide11.htm#1792411.
14 These numbers represent a single supply on, with fans on high setting at 100V, 200V, -40V DC.
15 Thermal rating, like current, is based on drive type/speed. This value is relatively constant regardless of input voltage, so only one value is required for each.

 

FC Switch Support—Tape/SAN
Vendor Model
Brocade Silkworm 2400/2800 (TapeSAN only)
Brocade Silkworm 3200/3250/3800/3850/3900/4100/12000/24000/200E/48000
McData ES 3016/3032, Intrepid 6064/6140/ED-5000, Sphereon 3216/3232/4300/4400/4500/4700
Qlogic 5600/5602
Cisco MDS 9120/9140/9216/9506/9509/9513/9124

FC = Fibre Channel; LVD = Low Voltage Differential.

NetApp Systems Cabinet
20A and 30A single-phase cabinets

20A Cabinet: Includes 4 power cords with NEMA L6-20 or IEC 309 or Australia AS/NZ53123-20 connectors

30A Cabinet: Includes 4 power cords with NEMA L6-30P or IEC 309

20A Cabinet: 1 FAS3100 chassis & 12 DS14-type shelves



30A Cabinet: 1 FAS3100 chassis & 12 DS-14 type shelves
AC Power 200 to 240VAC
Current 20A Cabinet: Maximum 32A total
30A Cabinet: Maximum 24A total
Dimensions (height/width/depth) 78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm)
Min. Clearances 48" (122 cm) front and rear
Shipping Height 90.6" (230 cm)
Weight (empty) 275 lb (125 kg)

 

V3100 Controller and System
Specifications
Active-Active
Configuration
Single Controller
Configuration
Controller Weight 122 lb (55.3 kg) 95 lb (43.1 kg)
Controller Height 10.2" (26 cm), fits into 6U space 10.24" (26 cm), fits into 6U space
Controller Width 19" IEC rack-compliant (17.6", 44.7 cm)
Controller Depth 24.3" (61.7 cm), 28" (71.1 cm) with cable management bracket
Operating Temperature, Altitude, and Relative Humidity 10° C to 40° C (50° F to 104° F); at </= 3,000 m (at </= 10,000' feet) elevation; 20% to 80% relative humidity, non-condensing (28° C wet bulb temperature)
Non operating Temperature and Relative Humidity -40° C to 70° C (-40° F to 158° F); 5% to 95% relative humidity, non-condensing, in original container
Operating Acoustic Noise ≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
Min. Cabinet Clearances for Airflow 10" (25.4 cm) in front, 12" (30.5 cm) in rear
Min. Cabinet Clearances for Service 30" (76.2 cm ) in front, 30" (76.2 cm) in rear
Compliance RoHS-compliant
Safety/Emissions/Immunity Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, GOST-R
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, BCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3

 

V3100 System Power Specifications
Model Input Voltage  
Active/Active
Single Controller
Typical
Maximum
Typical
Maximum
One
Side
Both
Sides
One
Side
Both
Sides
V3140 100-120VAC Current, A
2.99
5.97
7.38
1.89
3.77
3.98
Power, W
297
594
736
187
373
396
Thermal, BTU/hr
1013
2026
2509
636
1272
1350
200-240VAC Current, A
1.49
2.98
3.6
0.97
1.93
1.97
Power, W
291
581
712
183
366
385
Thermal,
BTU/hr
991
1981
2427
625
1249
1313
V3170 100-120VAC Current, A
4.07
8.14
9.74
2.37
4.74
5.07
Power, W
405
810
969
235
470
505
Thermal,
BTU/hr
1381
2761
3305
801
1602
1722
200-240VAC Current, A
2.02
4.03
4.69
1.19
2.38
2.52
Power, W
394
788
930
230
459
493
Thermal,
BTU/hr
1343
2686
3170
782
1564
1680