| Technical Highlights | |
| Maximum RAID Group Sizes |
RAID-DP™ (high performance RAID 6) FC – 28 (26 data disks plus 2 parity disks) SATA – 16 (14 data disks plus 2 parity disks) RAID 41 FC – 14 (13 data disks plus 1 parity disk) SATA – 7 (6 data disks plus 1 parity disk) SyncMirror® (high resiliency RAID 1) Options:
|
| SAN Protocol Support |
Fibre Channel Protocol (FCP) for SCSI (2Gb and 4Gb); fabric-attached and direct-attached; iSCSI |
| File Service Protocol Support |
NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft® CIFS |
| Other Protocol Support |
HTTP 1.0, HTTP 1.1 virtual hosts |
| LUNs |
Up to 2,048 front-end LUNs on FAS3040 and FAS3070; up to 1,024 front-end LUNs on FAS3020 |
| FlexVol® Volumes |
Up to 500 per controller |
| Volume/Aggregate Size2 |
16TB |
| Snapshot™ Copies |
Up to 127,000 |
| Number of Supported SAN Hosts |
Up to 4 ports per controller configured as front-end (host) connectivity ports Up to 4 directly connected servers (per controller and per active/active configuration) Up to 256 SAN connected servers (per controller and per active/active configuration) |
| Supported Configurations |
Highly Available Controller Configurations Active/active controller with Active-Active Controller3, active/active controller with stretch (non-switch) MetroCluster, active/active controller with Fabric-Attached MetroCluster4 Highly Available Back-End (Disk) Configurations Dual-path, Multipath HA Storage |
| Reliability |
Redundant hot-swappable controllers, cooling fans, power supplies, optics, and RJ-45 ports |
| Management |
Full-duplex 10/100/1000Base-T Ethernet onboard console, diagnostic LED/LCD, Remote LAN Management (RLM) Card5, SNMP, telnet, SSH, HTTP, Web (SSL), host scripting, e-mail alerts |
| Security |
Authentication: Kerberos (MIT/Active Directory) Authorization: LDAP, NIS Auditing: File access logging Encryption: IPSec, SSL, SSH, SMB signing Role Based Access Control (RBAC) |
| On-board I/O Ports/Slots | FAS3070 |
FAS3040 |
FAS3020 |
|||
Active/ Active Confi- guration |
Single Controller |
Active/ Active Confi- guration |
Single Controller |
Active/ Active Confi- guration |
Single Controller |
|
| Fibre Channel Ports (target or initiator) |
8 ports 1, 2, or 4Gb (auto-sensing) |
4 ports 1, 2, or 4Gb (auto-sensing) |
8 ports 1, 2, or 4Gb (auto-sensing) |
4 ports 1, 2, or 4Gb (auto-sensing) |
8 ports of 2Gb |
4 ports of 2Gb |
| GbE Ports |
8 |
4 |
8 |
4 |
8 |
4 |
| Ultra160 SCSI Ports |
N/A |
N/A |
N/A |
N/A |
2 |
1 |
| I/O Expansion Slots9 |
6 |
3 |
6 |
3 |
6 |
3 |
| I/O Card Support | FAS3070 |
FAS3040 |
FAS3020 |
|||
Active/ Active Confi- guration |
Single Controller |
Active/ Active Confi- guration |
Single Controller |
Active/ Active Confi- guration |
Single Controller |
|
| 2-port FC Disk Adapters (max.) |
6 |
3 |
6 |
3 |
6 |
3 |
| 2-port 4Gb FC Target Adapters (max.) |
4 |
2 |
4 |
2 |
4 |
2 |
| 4-port 4Gb FC Disk/Tape HBAs (max.) |
6 |
3 |
6 |
3 |
6 |
3 |
| 2-port Ultra320 SCSI Tape HBA |
6 |
3 |
6 |
3 |
6 |
3 |
| Optional Network/SAN Cards (max.) 2-port FC Tape Adapters 4-port 1GbE TOE (copper) cards 1-port 10GbE TOE (fiber) cards 2-port 10GbE TOE (fiber) cards10 2-port 1GbE (copper or fiber) cards 2-port 1Gb iSCSI (copper or fiber) HBA |
6 6 NA 6 6 6 |
3 3 NA 3 3 3 |
6 6 NA 6 6 6 |
3 3 NA 3 3 3 |
6 4 4 NA 6 6 |
3 2 2 NA 3 3 |
| Software | ||
| Operating System | NetApp Data ONTAP® | |
| Operating Systems Supported | Windows® 2000, Windows Server 2003, Windows XP, Linux®, Sun™ Solaris™, AIX, HP-UX, Mac® OS, VMware ESX | |
| Software Features | Standard RAID manager, including RAID-DP Snapshot Fast Boot NIS DNS FilerView® FlexVol™ FlexCache™ FlexShare™ Network Data Management Protocol (NDMP) Maintenance Center |
Licensed FlexClone® FlexCache® MultiStore® SnapMirror® SnapRestore® Single Mailbox Recovery SnapVault® LockVault™ SnapLock® Compliance SnapLock Enterprise SyncMirror MetroCluster NearStore® Personality Option Manageability Software Application Suite: SnapManager® for Microsoft Exchange SnapManager for Microsoft SQL Server SnapManager for Oracle Server Suite: ApplianceWatch™ for HP Openview ApplianceWatch for Tivoli® SnapDrive® for UNIX® SnapDrive for Windows Data Suite: Protection Manager™11 Virtual File Manager™ - EE Virtual File Manager - ME Storage Suite: CommandCentral Storage File Storage Resource Manager Operations Manager (formerly DFM) SAN Consolidation |
9 FAS3070 and FAS3040 have PCI-e I/O slots, while FAS3020 have PCI-x I/O slots.
1010GbE TOE (fiber) card will be available after the FAS3070 and FAS3040 are available. Please contact Network Appliance regarding availability.
11 Protection Manager was previously known as Business Continuance Option.
| Disk Drive Storage Expansion Shelf Specifications | |
| Storage Expansion Shelves Supported (Fibre Channel, SATA) |
FC: DS14mk4 FC DS14mk2 FC, DS14 (for upgrade migrations only) SATA: DS14mk2 AT All shelves have 14 bays for 3.5" low-profile FC or SATA disk drives |
| Storage Expansion Shelf to Controller Interface | Fibre Channel-Arbitrated Loop (FC-AL) |
| Storage Expansion Shelf Configurations |
New System Configurations FC: DS14mk4 FC with ESH4 (Embedded Switched Hub 4) Electronics SATA: DS14mk2 AT with AT-FCX Electronics AT-FCX Supported via Upgrade Migrations from Installed Systems FC: DS14mk4 FC with ESH4 Electronics DS14mk2 FC with ESH4 or ESH2 Electronics DS14 with ESH2 or ESH Electronics DS14 with LRC (Loop Resiliency Circuit) Electronics (FAS3020 only) SATA: DS14mk2 AT with AT-FCX Electronics |
| Power Supply/Cooling Fans |
Dual, redundant, hot-pluggable, integrated power supply/fan assemblies13 |
| AC Power/Max. Current14 |
SATA: 7200 RPM drives: 3.01 / 1.51 / 7.4A @ 100VAC / 200VAC / -40VDC FC: 10,000 RPM drives: 3.09 / 1.56/ 7.61A @ 100VAC / 200VAC / -40VDC FC: 15,000 RPM drives: 3.96 / 1.94/ 10.22A @ 100VAC / 200VAC / -40VDC |
| Thermal Rating15 |
SATA 7200 RPM drives: 1017 BTU/hr FC: 10,000 RPM drives: 1043 BTU//hr FC: 15,000 RPM drives: 1394 BTU/hr |
| Operating Acoustic Noise |
49 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) |
| Dimensions (height/width/depth) |
3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm) |
| Weight |
77 lb (35 kg) fully loaded |
| FC Switch Support—Tape/SAN | |
| Vendor |
Model |
| Brocade |
Silkworm 2400/2800 (TapeSAN only) |
| Brocade |
Silkworm 3200/3250/3800/3850/3900/4100/12000/24000/200E/48000 |
| McData |
ES 3016/3032, Intrepid 6064/6140/ED-5000, Sphereon 3216/3232/4300/4400/4500/4700 |
| Qlogic |
5600/5602 |
| Cisco |
MDS 9120/9140/9216/9506/9509/9513/9124 |
FC = Fibre Channel; LVD = Low Voltage Differential.
| NetApp Systems Cabinet | |
| 20A and 30A single-phase cabinets 20A Cabinet – Includes 4 power cords with NEMA L6-20 or IEC 309 or Australia AS/NZ53123-20 connectors 30A Cabinet – Includes 4 power cords with NEMA L6-30P or IEC 309 |
20A Cabinet – 1 controller & 13 DS14-type shelves; 2 controllers & 12 DS14-type shelves 30A Cabinet – 1 controller & 13 DS14-type shelves; 2 controllers & 12 DS-14 type shelves |
| AC Power |
200 to 240VAC |
| Current |
20A Cabinet - Maximum 32A total 30A Cabinet - Maximum 24A total |
| Dimensions (height/width/depth) |
78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm) |
| Min. Clearances |
48" (122 cm) front and rear |
| Shipping Height |
90.6" (230 cm) |
| Weight (empty) |
275 lb (125 kg) |
13 For detailed disk shelf specifications, refer to http://now.netapp.com/NOW/knowledge/docs/hardware/NetApp/site/guide11.htm#1792411.
14 These numbers represent a single supply on, with fans on high setting at 100V, 200V, -40V DC.
15 Thermal rating, like current, is based on drive type/speed. This value is relatively constant regardless of input voltage, so only one value is required for each.
| FAS System Specifications | Active/Active Configuration | Single Controller Configuration |
| Controller Weight |
150 lb (68 kg) |
75 lb (34 kg) |
| Controller Height |
10.24" (26 cm), fits into 6U space |
5.12" (13 cm), fits into 3U space |
| Controller Width |
19" IEC rack-compliant (17.7", 44.9 cm) |
|
| Controller Depth |
24" (61 cm), 30" (76.2 cm) with cable management bracket |
|
| Operating Temperature, Altitude, and Relative Humidity |
10° C to 40° C (50° F to 104° F); at </= 3,000 m (at </= 10,000') elevation; 20% to 80% relative humidity, non-condensing (28° C wet bulb temperature) |
|
| Non-operating Temperature and Relative Humidity |
-40° C to 65° C (-40° F to 149° F); 10% to 95% relative humidity, non-condensing, in original container |
|
| Operating Acoustic Noise |
≤ 54 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) |
|
| Min. Cabinet Clearances for Airflow |
10" (25.4 cm) in front, 12" (30.5 cm) in rear |
|
| Min. Cabinet Clearances for Service |
30" (76.2 cm ) in front, 30" (76.2 cm) in rear |
|
| Compliance |
RoHS-compliant |
|
| Safety/Emissions/Immunity |
Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, MIC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, CoC (South Africa), BSMI |
|
| Model | Input Voltage | Active/Active |
Single Controller |
|||||
Typical |
Maximum | Typical |
Maximum | |||||
One side |
Both sides |
One side |
Both sides |
|||||
| FAS3020 | 100-120VAC | Current, A | .2.4 |
4.8 |
6.8 |
1.2 |
2.4 |
3.4 |
| Power, W | 236 |
472 |
672 |
118 |
236 |
336 |
||
| Thermal, BTU/hr | 805 |
1610 |
2288 |
402.5 |
805 |
1144 |
||
| 200-240VAC | Current, A | 1.4 |
2.8 |
3.6 |
0.7 |
1.4 |
1.8 |
|
| Power, W | 229 |
458 |
658 |
114.5 |
229 |
329 |
||
| Thermal, BTU/hr | 783 |
1566 |
2244 |
391.5 |
783 |
1122 |
||
| -40 to -60VDC | Current, A | 5.7 |
11.4 |
16.4 |
2.85 |
5.7 |
8.2 |
|
| Power, W | 226 |
452 |
656 |
113 |
226 |
328 |
||
| Thermal, BTU/hr | 771 |
1542 |
2236 |
385.5 |
771 |
1118 |
||
| FAS3040 | 100-120VAC | Current, A | 3.4 |
6.8 |
7.4 |
1.7 |
3.4 |
3.7 |
| Power, W | 338 |
676 |
726 |
169 |
338 |
363 |
||
| Thermal, BTU/hr | 1152 |
2304 |
2476 |
576 |
1152 |
1238 |
||
| 200-240VAC | Current, A | 1.9 |
3.8 |
3.8 |
0.95 |
1.9 |
1.9 |
|
| Power, W | 330 |
660 |
716 |
165 |
330 |
358 |
||
| Thermal, BTU/hr | 1127 |
2254 |
2442 |
563.5 |
1127 |
1221 |
||
| -40 to -60VDC | Current, A | 7.4 |
14.8 |
15.88 |
3.7 |
7.4 |
7.94 |
|
| Power, W | 296 |
592 |
636 |
148 |
296 |
318 |
||
| Thermal, BTU/hr | 1011 |
2022 |
2168 |
505.5 |
1011 |
1084 |
||
| FAS3070 | 100-120VAC | Current, A | 3.7 |
7.4 |
8 |
1.85 |
3.7 |
4 |
| Power, W | 361 |
722 |
800 |
180.5 |
361 |
400 |
||
| Thermal, BTU/hr | 1233 |
2466 |
2730 |
616.5 |
1233 |
1365 |
||
| 200-240VAC | Current, A | 2.1 |
4.2 |
4.2 |
1.05 |
2.1 |
2.1 |
|
| Power, W | 355 |
710 |
774 |
177.5 |
355 |
387 |
||
| Thermal, BTU/hr | 1212 |
2424 |
2640 |
606 |
1212 |
1320 |
||
| -40 to -60VDC | Current, A | 9.4 |
18.8 |
21.2 |
4.7 |
9.4 |
10.6 |
|
| Power, W | 376 |
752 |
846 |
188 |
376 |
423 |
||
| Thermal, BTU/hr | 1283 |
2566 |
2884 |
641.5 |
1283 |
1442 |
||