NetApp FAS3000 Series Specification

Technical Highlights
Maximum RAID Group Sizes
RAID-DP™ (high performance RAID 6)
FC – 28  (26 data disks plus 2 parity disks)
SATA – 16 (14 data disks plus 2 parity disks)

RAID 41
FC – 14 (13 data disks plus 1 parity disk)
SATA – 7 (6 data disks plus 1 parity disk)

SyncMirror® (high resiliency RAID 1)
Options:
  1. RAID-DP + RAID 1
  2. RAID 4 + RAID 1
SAN Protocol Support
Fibre Channel Protocol (FCP) for SCSI (2Gb and 4Gb); fabric-attached and direct-attached; iSCSI
File Service Protocol Support
NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft® CIFS
Other Protocol Support
HTTP 1.0, HTTP 1.1 virtual hosts
LUNs
Up to 2,048 front-end LUNs on FAS3040 and FAS3070; up to 1,024 front-end LUNs on FAS3020
FlexVol® Volumes
Up to 500 per controller
Volume/Aggregate Size2
16TB
Snapshot™ Copies
Up to 127,000
Number of Supported SAN Hosts
Up to 4 ports per controller configured as front-end (host) connectivity ports
Up to 4 directly connected servers (per controller and per active/active configuration)
Up to 256 SAN connected servers (per controller and per active/active configuration)
Supported Configurations
Highly Available Controller Configurations
Active/active controller with Active-Active Controller3, active/active controller with stretch (non-switch) MetroCluster, active/active controller with Fabric-Attached MetroCluster4

Highly Available Back-End (Disk) Configurations
Dual-path, Multipath HA Storage
Reliability
Redundant hot-swappable controllers, cooling fans, power supplies, optics, and RJ-45 ports
Management
Full-duplex 10/100/1000Base-T Ethernet onboard console, diagnostic LED/LCD, Remote LAN Management (RLM) Card5, SNMP, telnet, SSH, HTTP, Web (SSL), host scripting, e-mail alerts
Security
Authentication: Kerberos (MIT/Active Directory)
Authorization: LDAP, NIS
Auditing: File access logging
Encryption: IPSec, SSL, SSH, SMB signing
Role Based Access Control (RBAC)

 

On-board I/O Ports/Slots
FAS3070
FAS3040
FAS3020
 
Active/
Active
Confi-
guration
Single
Controller
Active/
Active
Confi-
guration
Single
Controller
Active/
Active
Confi-
guration
Single
Controller
Fibre Channel Ports
(target or initiator)
8 ports
1, 2, or 4Gb
(auto-sensing)
4 ports
1, 2, or 4Gb
(auto-sensing)
8 ports
1, 2, or 4Gb
(auto-sensing)
4 ports
1, 2, or 4Gb
(auto-sensing)
8 ports of 2Gb
4 ports of 2Gb
GbE Ports
8
4
8
4
8
4
Ultra160 SCSI Ports
N/A
N/A
N/A
N/A
2
1
I/O Expansion Slots9
6
3
6
3
6
3

 

I/O Card Support
FAS3070
FAS3040
FAS3020
 
Active/
Active
Confi-
guration
Single
Controller
Active/
Active
Confi-
guration
Single
Controller
Active/
Active
Confi-
guration
Single
Controller
2-port FC Disk Adapters (max.)
6
3
6
3
6
3
2-port 4Gb FC Target Adapters (max.)
4
2
4
2
4
2
4-port 4Gb FC Disk/Tape HBAs (max.)
6
3
6
3
6
3
2-port Ultra320 SCSI Tape HBA
6
3
6
3
6
3
Optional Network/SAN Cards (max.)
2-port FC Tape Adapters
4-port 1GbE TOE (copper) cards
1-port 10GbE TOE (fiber) cards
2-port 10GbE TOE (fiber) cards10
2-port 1GbE (copper or fiber) cards
2-port 1Gb iSCSI (copper or fiber) HBA

6
6
NA
6
6
6

3
3
NA
3
3
3

6
6
NA
6
6
6

3
3
NA
3
3
3

6
4
4
NA
6
6

3
2
2
NA
3
3

 

Software
Operating System NetApp Data ONTAP®
Operating Systems Supported Windows® 2000, Windows Server 2003, Windows XP, Linux®, Sun™ Solaris™, AIX, HP-UX, Mac® OS, VMware ESX
Software Features Standard
RAID manager, including RAID-DP
Snapshot
Fast Boot
NIS
DNS
FilerView®
FlexVol
FlexCache
FlexShare
Network Data Management Protocol (NDMP)
Maintenance Center
Licensed
FlexClone®
FlexCache®
MultiStore®
SnapMirror®
SnapRestore®
Single Mailbox Recovery
SnapVault®
LockVault
SnapLock® Compliance
SnapLock Enterprise
SyncMirror
MetroCluster
NearStore® Personality Option
Manageability Software
Application Suite:
   SnapManager® for Microsoft Exchange
   SnapManager for Microsoft SQL Server
   SnapManager for Oracle
Server Suite:
    ApplianceWatch™ for HP Openview
    ApplianceWatch for Tivoli®
    SnapDrive® for UNIX®
    SnapDrive for Windows
Data Suite:
    Protection Manager11
    Virtual File Manager™ - EE
    Virtual File Manager - ME
Storage Suite:
    CommandCentral Storage
    File Storage Resource Manager
    Operations Manager (formerly DFM)
    SAN Consolidation

9 FAS3070 and FAS3040 have PCI-e I/O slots, while FAS3020 have PCI-x I/O slots.
1010GbE TOE (fiber) card will be available after the FAS3070 and FAS3040 are available. Please contact Network Appliance regarding availability.
11 Protection Manager was previously known as Business Continuance Option.

 

Disk Drive Storage Expansion Shelf Specifications
Storage Expansion Shelves Supported (Fibre Channel, SATA)
FC: DS14mk4 FC
DS14mk2 FC, DS14 (for upgrade migrations only)
SATA: DS14mk2 AT
All shelves have 14 bays for 3.5" low-profile FC or SATA disk drives
Storage Expansion Shelf to Controller Interface Fibre Channel-Arbitrated Loop (FC-AL)
Storage Expansion Shelf Configurations
New System Configurations
FC: DS14mk4 FC with ESH4 (Embedded Switched Hub 4) Electronics
SATA: DS14mk2 AT with AT-FCX Electronics
AT-FCX

Supported via Upgrade Migrations from Installed Systems
FC: DS14mk4 FC with ESH4 Electronics
DS14mk2 FC with ESH4 or ESH2 Electronics
DS14 with ESH2 or ESH Electronics
DS14 with LRC (Loop Resiliency Circuit) Electronics (FAS3020 only)
SATA: DS14mk2 AT with AT-FCX Electronics
Power Supply/Cooling Fans
Dual, redundant, hot-pluggable, integrated power supply/fan assemblies13
AC Power/Max. Current14
SATA: 7200 RPM drives: 3.01 / 1.51 / 7.4A @ 100VAC / 200VAC / -40VDC
FC: 10,000 RPM drives: 3.09 / 1.56/ 7.61A @ 100VAC / 200VAC / -40VDC
FC: 15,000 RPM drives: 3.96 / 1.94/ 10.22A @ 100VAC / 200VAC / -40VDC
Thermal Rating15
SATA 7200 RPM drives: 1017 BTU/hr
FC: 10,000 RPM drives: 1043 BTU//hr
FC: 15,000 RPM drives: 1394 BTU/hr
Operating Acoustic Noise
49 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
Dimensions (height/width/depth)
3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm)
Weight
77 lb (35 kg) fully loaded

 

FC Switch Support—Tape/SAN
Vendor
Model
Brocade
Silkworm 2400/2800 (TapeSAN only)
Brocade
Silkworm 3200/3250/3800/3850/3900/4100/12000/24000/200E/48000
McData
ES 3016/3032, Intrepid 6064/6140/ED-5000, Sphereon 3216/3232/4300/4400/4500/4700
Qlogic
5600/5602
Cisco
MDS 9120/9140/9216/9506/9509/9513/9124

FC = Fibre Channel; LVD = Low Voltage Differential.

 

NetApp Systems Cabinet
20A and 30A single-phase cabinets

20A Cabinet – Includes 4 power cords with NEMA L6-20 or IEC 309 or Australia AS/NZ53123-20 connectors

30A Cabinet – Includes 4 power cords with NEMA L6-30P or IEC 309
20A Cabinet – 1 controller & 13 DS14-type shelves; 2 controllers & 12 DS14-type shelves

30A Cabinet – 1 controller & 13 DS14-type shelves; 2 controllers & 12 DS-14 type shelves
AC Power
200 to 240VAC
Current
20A Cabinet - Maximum 32A total
30A Cabinet - Maximum 24A total

Dimensions (height/width/depth)
78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm)
Min. Clearances
48" (122 cm) front and rear
Shipping Height
90.6" (230 cm)
Weight (empty)
275 lb (125 kg)

13 For detailed disk shelf specifications, refer to http://now.netapp.com/NOW/knowledge/docs/hardware/NetApp/site/guide11.htm#1792411.
14 These numbers represent a single supply on, with fans on high setting at 100V, 200V, -40V DC.
15 Thermal rating, like current, is based on drive type/speed. This value is relatively constant regardless of input voltage, so only one value is required for each.

 

FAS System Specifications Active/Active Configuration Single Controller Configuration
Controller Weight
150 lb (68 kg)
75 lb (34 kg)
Controller Height
10.24" (26 cm), fits into 6U space
5.12" (13 cm), fits into 3U space
Controller Width
19" IEC rack-compliant (17.7", 44.9 cm)
Controller Depth
24" (61 cm), 30" (76.2 cm) with cable management bracket
Operating Temperature, Altitude, and Relative Humidity
10° C to 40° C (50° F to 104° F); at </= 3,000 m (at </= 10,000') elevation; 20% to 80% relative humidity, non-condensing (28° C wet bulb temperature)
Non-operating Temperature and Relative Humidity
-40° C to 65° C (-40° F to 149° F); 10% to 95% relative humidity, non-condensing, in original container
Operating Acoustic Noise
54 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
Min. Cabinet Clearances for Airflow
10" (25.4 cm) in front, 12" (30.5 cm) in rear
Min. Cabinet Clearances for Service
30" (76.2 cm ) in front, 30" (76.2 cm) in rear
Compliance
RoHS-compliant
Safety/Emissions/Immunity
Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI

Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, MIC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, CoC (South Africa), BSMI

 

Model Input Voltage  
Active/Active
Single Controller
Typical
Maximum
Typical
Maximum
One side
Both sides
One side
Both sides
FAS3020 100-120VAC Current, A
.2.4
4.8
6.8
1.2
2.4
3.4
  Power, W
236
472
672
118
236
336
  Thermal, BTU/hr
805
1610
2288
402.5
805
1144
200-240VAC Current, A
1.4
2.8
3.6
0.7
1.4
1.8
  Power, W
229
458
658
114.5
229
329
  Thermal, BTU/hr
783
1566
2244
391.5
783
1122
-40 to -60VDC Current, A
5.7
11.4
16.4
2.85
5.7
8.2
  Power, W
226
452
656
113
226
328
  Thermal, BTU/hr
771
1542
2236
385.5
771
1118
FAS3040 100-120VAC Current, A
3.4
6.8
7.4
1.7
3.4
3.7
  Power, W
338
676
726
169
338
363
  Thermal, BTU/hr
1152
2304
2476
576
1152
1238
200-240VAC Current, A
1.9
3.8
3.8
0.95
1.9
1.9
  Power, W
330
660
716
165
330
358
  Thermal, BTU/hr
1127
2254
2442
563.5
1127
1221
-40 to -60VDC Current, A
7.4
14.8
15.88
3.7
7.4
7.94
  Power, W
296
592
636
148
296
318
  Thermal, BTU/hr
1011
2022
2168
505.5
1011
1084
FAS3070 100-120VAC Current, A
3.7
7.4
8
1.85
3.7
4
  Power, W
361
722
800
180.5
361
400
  Thermal, BTU/hr
1233
2466
2730
616.5
1233
1365
200-240VAC Current, A
2.1
4.2
4.2
1.05
2.1
2.1
  Power, W
355
710
774
177.5
355
387
  Thermal, BTU/hr
1212
2424
2640
606
1212
1320
-40 to -60VDC Current, A
9.4
18.8
21.2
4.7
9.4
10.6
  Power, W
376
752
846
188
376
423
  Thermal, BTU/hr
1283
2566
2884
641.5
1283
1442